Gas Discharge Tube (GDT) Protectors

HUBER+SUHNER Gas Discharge Tube (GDT) Protectors utilize GDT technology, making them ideal for applications with RF and DC components on the antenna line. These electromagnetic pulse (EMP) protectors make the best of the traditional spark gap protection principle for general applications in electronics and adapt it to RF coaxial line applications. The protectors are generally designed as coaxial feed-through devices for 50Ω or 75Ω systems. They offer DC continuity for remote powering and broadband usage from DC up to 1GHz. HUBER+SUHNER GDT Protectors feature replaceable gas discharge tubes and easy maintenance.

Mga Resulta: 24
Pumili Larawan # ng Piyesa Mfr. Paglalarawan Datasheet Availability Pagpepresyo (PHP) I-filter ang mga resulta sa talahanayan ayon sa unit price batay sa iyong dami. Dami RoHS ECAD Model Peak Pulse Current DC Sparkover Dami ng Electrode Failsafe na Proteksiyon O/H Diyametro Haba Minimum na Operating Temperature Maximum na Operating Temperature
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 350 V 163May Stock
Min.: 1
Mult.: 1
30 kA 350 V 2 Electrode Failsafe Protected 8 mm 6 mm - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 470 V with holder 5May Stock
Min.: 1
Mult.: 1
30 kA 470 V 2 Electrode Failsafe Protected - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 1200 V 7May Stock
Min.: 1
Mult.: 1
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors 9May Stock
Min.: 1
Mult.: 1

HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 230 V 2,912May Stock
Min.: 1
Mult.: 1
30 kA 230 V 2 Electrode Failsafe Protected 8 mm 6 mm - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 90 V with holder 17May Stock
Min.: 1
Mult.: 1
30 kA 90 V 2 Electrode Failsafe Protected - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 90 V 65May Stock
40Inaasahan 6/8/2026
Min.: 1
Mult.: 1
30 kA 90 V 2 Electrode Failsafe Protected 8 mm 6 mm - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube, 350 V 6May Stock
Min.: 1
Mult.: 1
30 kA 350 V 2 Electrode Failsafe Protected 15 mm 16.2 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 470 V
107Inaasahan 7/22/2026
Min.: 1
Mult.: 1
30 kA 470 V 2 Electrode Failsafe Protected 8 mm 6 mm - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 230 V with holder
12Inaasahan 8/5/2026
Min.: 1
Mult.: 1
30 kA 230 V 2 Electrode Failsafe Protected - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 600 V
25Inaasahan 6/22/2026
Min.: 1
Mult.: 1
30 kA 600 V 2 Electrode Failsafe Protected 8 mm 6 mm - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube, 230 V
17Inaasahan 6/29/2026
Min.: 1
Mult.: 1

30 kA 230 V 2 Electrode Failsafe Protected 15 mm 16.2 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube, 90 V
6Inaasahan 7/22/2026
Min.: 1
Mult.: 1
30 kA 90 V 2 Electrode Failsafe Protected 15 mm 16.2 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube, 600 V
12Inoorder
Min.: 1
Mult.: 1
30 kA 600 V 2 Electrode Failsafe Protected 15 mm 16.2 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube 230 V (for series 3402 platform 3000)
12Inaasahan 7/13/2026
Min.: 1
Mult.: 1
30 kA 230 V 2 Electrode Failsafe Protected 15 mm 19.4 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube 90 V (for series 3402 platform 3000)
10Inaasahan 7/21/2026
Min.: 1
Mult.: 1
30 kA 90 V 2 Electrode Failsafe Protected 15 mm 19.4 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 900V Lead-Time para sa Hindi Naka-stock 12 (na) Linggo
Min.: 1
Mult.: 1

HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 350 V with holder Lead-Time para sa Hindi Naka-stock 12 (na) Linggo
Min.: 1
Mult.: 1
30 kA 350 V 2 Electrode Failsafe Protected - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Gas discharge tube 600 V with holder Lead-Time para sa Hindi Naka-stock 12 (na) Linggo
Min.: 1
Mult.: 1
30 kA 600 V 2 Electrode Failsafe Protected - 40 C + 85 C
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube, 470 V Lead-Time para sa Hindi Naka-stock 12 (na) Linggo
Min.: 1
Mult.: 1
30 kA 470 V 2 Electrode Failsafe Protected 15 mm 16.2 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube 230 V (for series 3409) Lead-Time para sa Hindi Naka-stock 12 (na) Linggo
Min.: 1
Mult.: 1
30 kA 230 V 2 Electrode Failsafe Protected 24 mm 21.6 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube 90 V (for series 3409) Lead-Time para sa Hindi Naka-stock 12 (na) Linggo
Min.: 1
Mult.: 1
30 kA 90 V 2 Electrode Failsafe Protected 24 mm 21.6 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube 350 V (for series 3402 platform 3000) Lead-Time para sa Hindi Naka-stock 10 (na) Linggo
Min.: 1
Mult.: 1
30 kA 350 V 2 Electrode Failsafe Protected 15 mm 19.4 mm
HUBER+SUHNER Gas Discharge Tubes - GDTs / Gas Plasma Arrestors SEMPER Gas Discharge Tube 470 V (for series 3402 platform 3000) Lead-Time para sa Hindi Naka-stock 10 (na) Linggo
Min.: 1
Mult.: 1
30 kA 470 V 2 Electrode Failsafe Protected 15 mm 19.4 mm