MCS1806 Hall-effect Current Sensors

Monolithic Power Systems (MPS) MCS1806 Hall-effect Current Sensors are 3kVRMS isolated current sensors with 500VRMS working voltage and ±2.5% accuracy. These linear Hall-effect current sensors for AC or DC current sensing incorporate differential Hall arrays that cancel out any stray magnetic fields. The MCS1806 current sensors feature ±5A to ±50A bidirectional range, adjustable bandwidth up to 100kHz, and ratio-metric outputs from the supply voltages. These Hall-effect sensors are available in SOIC-8 packages, which are factory-trimmed for accuracy and offer no magnetic Hysteresis. The MCS1806 Hall-effect current sensors are ideally used in multi-phase inverters, motor controls, automotive systems, Switch-Mode Power Supplies (SMPSs), over-current fault protection, and load detection and management.

Mga Resulta: 23
Pumili Larawan # ng Piyesa Mfr. Paglalarawan Datasheet Availability Pagpepresyo (PHP) I-filter ang mga resulta sa talahanayan ayon sa unit price batay sa iyong dami. Dami RoHS ECAD Model Rating ng Current Uri ng Sensor Tagal ng Pagtugon Katumpakan Range ng Frequency Supply Voltage ng Pagpapatakbo Uri ng Output Maximum na Operating Temperature Minimum na Operating Temperature Package / Case Supply Voltage - Max Supply Voltage - Min Uri
Monolithic Power Systems (MPS) Board Mount Current Sensors 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 970May Stock
Min.: 1
Mult.: 1
: 500

30 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 2,453May Stock
Min.: 1
Mult.: 1
: 500

40 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 337May Stock
Min.: 1
Mult.: 1
: 500

40 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 533May Stock
Min.: 1
Mult.: 1
: 500

20 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 2,495May Stock
Min.: 1
Mult.: 1
: 2,500

20 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation 75May Stock
10,000Inoorder
Min.: 1
Mult.: 1
: 2,500

5 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 367May Stock
Min.: 1
Mult.: 1
: 500

5 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 104May Stock
Min.: 1
Mult.: 1
: 500

20 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 177May Stock
Min.: 1
Mult.: 1
: 500

50 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 5V Hall current sensor. 2.5% accuracy. 3kV Isolation 28May Stock
Min.: 1
Mult.: 1
: 500

10 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation
895Inoorder
Min.: 1
Mult.: 1
: 500

5 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation
500Inaasahan 10/19/2026
Min.: 1
Mult.: 1
: 500

30 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation
498Inaasahan 12/8/2026
Min.: 1
Mult.: 1
: 500

50 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation Lead-Time 64 (na) Linggo
Min.: 1
Mult.: 1
: 500

10 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation Lead-Time para sa Hindi Naka-stock 57 (na) Linggo
Min.: 1
Mult.: 1
: 2,500

30 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation Lead-Time para sa Hindi Naka-stock 57 (na) Linggo
Min.: 2,500
Mult.: 2,500
: 2,500

40 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 3.3V Hall current sensor. 2.5% accuracy. 3kV Isolation Lead-Time para sa Hindi Naka-stock 57 (na) Linggo
Min.: 2,500
Mult.: 2,500
: 2,500

50 A Current Sense 5 us 2.5 % 100 kHz 3.3 V Analog + 125 C - 40 C SOIC-8 3.6 V 3 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Lead-Time para sa Hindi Naka-stock 57 (na) Linggo
Min.: 2,500
Mult.: 2,500
: 2,500

5 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Lead-Time para sa Hindi Naka-stock 57 (na) Linggo
Min.: 2,500
Mult.: 2,500
: 2,500

10 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Lead-Time para sa Hindi Naka-stock 57 (na) Linggo
Min.: 2,500
Mult.: 2,500
: 2,500

20 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Lead-Time para sa Hindi Naka-stock 57 (na) Linggo
Min.: 2,500
Mult.: 2,500
: 2,500

30 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Lead-Time para sa Hindi Naka-stock 57 (na) Linggo
Min.: 2,500
Mult.: 2,500
: 2,500

40 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect
Monolithic Power Systems (MPS) Board Mount Current Sensors 5V Hall current sensor. 2.5% accuracy. 3kV Isolation Lead-Time para sa Hindi Naka-stock 57 (na) Linggo
Min.: 2,500
Mult.: 2,500
: 2,500

50 A Current Sense 5 us 2.5 % 100 kHz 5 V Analog + 125 C - 40 C SOIC-8 5.5 V 4.5 V Isolated Hall-Effect